名称 |
防爆全新风(热回收)一体机系列 |
|||||||||||||
风机段 |
风量M³/H |
2000 |
3000 |
4000 |
5000 |
6000 |
7000 |
8000 |
9000 |
10000 |
11000 |
12000 |
13000 |
|
机外静压Pa |
200 |
300 |
300 |
300 |
400 |
400 |
400 |
500 |
500 |
500 |
500 |
600 |
||
电机功率KW |
1.1 |
1.5 |
1.5 |
2.2 |
3 |
3 |
4 |
5.5 |
7.5 |
7.5 |
7.5 |
7.5 |
||
表冷段 |
新风冷量kw |
4RX |
24 |
36 |
48 |
60 |
72 |
84 |
96 |
108 |
120 |
132 |
144 |
156 |
6RX |
31.2 |
46.8 |
62.4 |
78 |
93.6 |
109.2 |
124.8 |
140.4 |
156 |
171.6 |
187.2 |
202.8 |
||
8RX |
34 |
51 |
68 |
85 |
102 |
119 |
136 |
153 |
170 |
187 |
204 |
221 |
||
冷冻水管径 DN/4RX |
32 |
32 |
40 |
40 |
50 |
50 |
50 |
65 |
65 |
65 |
65 |
80 |
||
冷冻水管径 DN/6RX |
32 |
40 |
50 |
50 |
50 |
65 |
65 |
65 |
80 |
80 |
80 |
80 |
||
冷冻水管径 DN/8RX |
32 |
40 |
50 |
50 |
50 |
65 |
65 |
65 |
80 |
80 |
80 |
80 |
||
冷冻水 流量 |
(M³/H) 4RX |
4.13 |
6.19 |
8.26 |
10.32 |
12.38 |
14.45 |
16.51 |
18.58 |
20.64 |
22.70 |
24.77 |
26.83 |
|
冷冻水 流量 |
(M³/H) 6RX |
5.37 |
8.05 |
10.73 |
13.42 |
16.10 |
18.78 |
21.47 |
24.15 |
26.83 |
29.52 |
32.20 |
34.88 |
|
冷冻水 流量 |
(M³/H) 8RX |
5.85 |
8.77 |
11.70 |
14.62 |
17.54 |
20.47 |
23.39 |
26.32 |
29.24 |
32.16 |
35.09 |
40.94 |
|
加热段 |
热水加热量KW |
24 |
36 |
48 |
60 |
72 |
84 |
96 |
108 |
120 |
132 |
144 |
156 |
|
热水管径DN |
32 |
32 |
40 |
40 |
50 |
50 |
50 |
65 |
65 |
65 |
65 |
80 |
||
电加热补偿量KW |
8 |
10 |
15 |
18 |
20 |
25 |
30 |
30 |
35 |
40 |
42 |
45 |
||
加湿段 |
电极加湿量Kg/H |
13 |
19 |
25 |
32 |
38 |
44 |
50 |
57 |
63 |
69 |
76 |
82 |
|
干蒸汽加湿量 |
||||||||||||||
机组噪声db |
≤65 |
≤65 |
≤65 |
≤65 |
≤70 |
≤70 |
≤70 |
≤70 |
≤70 |
≤72 |
≤72 |
≤74 |
||
防爆等级 |
ExdibmbIIBT4Gb |
名称 |
防爆全新风(热回收)一体机系列 |
||||||||||||
风机段 |
风量M³/H |
14000 |
15000 |
16000 |
17000 |
18000 |
19000 |
20000 |
22000 |
25000 |
28000 |
30000 |
|
机外静压Pa |
600 |
600 |
600 |
600 |
600 |
600 |
700 |
700 |
700 |
700 |
700 |
||
电机功率KW |
7.5 |
7.5 |
7.5 |
11 |
11 |
11 |
11 |
11 |
15 |
15 |
15 |
||
表冷段 |
新风冷量kw |
4RX |
168 |
180 |
192 |
204 |
216 |
228 |
240 |
264 |
300 |
336 |
360 |
6RX |
218.4 |
234 |
249.6 |
265.2 |
280.8 |
296.4 |
312 |
343.2 |
390 |
436.8 |
468 |
||
8RX |
238 |
255 |
272 |
289 |
306 |
323 |
340 |
374 |
425 |
476 |
510 |
||
冷冻水管径 DN/4RX |
80 |
80 |
80 |
80 |
80 |
80 |
100 |
100 |
100 |
100 |
100 |
||
冷冻水管径 DN/6RX |
80 |
80 |
80 |
100 |
100 |
100 |
100 |
100 |
125 |
125 |
125 |
||
冷冻水管径 DN/8RX |
80 |
100 |
100 |
100 |
100 |
100 |
100 |
100 |
125 |
125 |
125 |
||
冷冻水 流量 |
(M³/H) 4RX |
28.90 |
30.96 |
33.02 |
35.09 |
37.15 |
39.22 |
41.28 |
45.41 |
51.60 |
57.79 |
61.92 |
|
冷冻水 流量 |
(M³/H) 6RX |
37.56 |
40.25 |
42.93 |
45.61 |
48.30 |
50.98 |
53.66 |
59.03 |
67.08 |
75.13 |
80.50 |
|
冷冻水 流量 |
(M³/H) 8RX |
40.94 |
43.86 |
46.78 |
49.71 |
52.63 |
55.56 |
58.48 |
64.33 |
73.10 |
81.87 |
87.72 |
|
加热段 |
热水加热量KW |
168 |
180 |
192 |
204 |
216 |
228 |
240 |
264 |
300 |
336 |
360 |
|
热水管径DN |
80 |
80 |
80 |
80 |
80 |
80 |
100 |
100 |
100 |
100 |
100 |
||
电加热补偿量KW |
50 |
52 |
55 |
60 |
63 |
65 |
70 |
75 |
90 |
100 |
105 |
||
加湿段 |
电极加湿量Kg/H |
88 |
95 |
101 |
107 |
113 |
120 |
126 |
139 |
158 |
176 |
189 |
|
干蒸汽加湿量 |
|||||||||||||
机组噪声db |
≤76 |
≤74 |
≤78 |
≤76 |
≤78 |
≤78 |
≤79 |
≤79 |
≤80 |
≤80 |
≤82 |
||
防爆等级 |
ExdibmbIIBT4Gb |
名称 |
防爆全新风(热回收)一体机系列 |
||||||||||||
风机段 |
风量M³/H |
35000 |
40000 |
45000 |
50000 |
55000 |
60000 |
70000 |
80000 |
90000 |
100000 |
120000 |
|
机外静压Pa |
800 |
800 |
800 |
900 |
900 |
900 |
900 |
1000 |
1200 |
1200 |
1300 |
||
电机功率KW |
18.5 |
22 |
30 |
30 |
30 |
37 |
22×2 |
30×2 |
30×2 |
37×2 |
30×3 |
||
表冷段 |
新风冷量kw |
4RX |
420 |
480 |
540 |
600 |
660 |
720 |
840 |
960 |
1080 |
1200 |
1440 |
6RX |
546 |
624 |
702 |
780 |
858 |
936 |
1092 |
1248 |
1404 |
1560 |
1872 |
||
8RX |
595 |
680 |
765 |
850 |
935 |
1020 |
1190 |
1360 |
1530 |
1700 |
2040 |
||
冷冻水管径 DN/4RX |
125 |
125 |
125 |
150 |
150 |
150 |
150 |
200 |
200 |
200 |
200 |
||
冷冻水管径 DN/6RX |
150 |
150 |
150 |
150 |
150 |
200 |
200 |
200 |
200 |
200 |
200 |
||
冷冻水管径 DN/8RX |
150 |
150 |
150 |
150 |
150 |
200 |
200 |
200 |
200 |
200 |
200 |
||
冷冻水 流量 |
(M³/H) 4RX |
72.24 |
82.56 |
92.88 |
103.20 |
113.52 |
123.84 |
144.48 |
165.12 |
185.76 |
206.40 |
247.68 |
|
冷冻水 流量 |
(M³/H) 6RX |
93.91 |
107.33 |
120.74 |
134.16 |
147.58 |
160.99 |
187.82 |
214.66 |
214.99 |
268.32 |
321.98 |
|
冷冻水 流量 |
(M³/H) 8RX |
102.34 |
116.96 |
131.58 |
146.20 |
160.82 |
175.44 |
204.68 |
233.92 |
263.16 |
292.40 |
350.88 |
|
加热段 |
热水加热量KW |
420 |
480 |
540 |
600 |
660 |
720 |
840 |
960 |
1080 |
1200 |
1440 |
|
热水管径DN |
125 |
125 |
125 |
150 |
150 |
150 |
150 |
200 |
200 |
200 |
200 |
||
电加热补偿量KW |
125 |
140 |
160 |
175 |
195 |
210 |
245 |
285 |
315 |
350 |
420 |
||
加湿段 |
电极加湿量Kg/H |
221 |
252 |
284 |
315 |
347 |
378 |
441 |
504 |
567 |
630 |
756 |
|
干蒸汽加湿量 |
|||||||||||||
机组噪声db |
≤82 |
≤82 |
≤84 |
≤84 |
≤83 |
≤85 |
≤86 |
≤89 |
≤90 |
≤89 |
≤92 |
||
防爆等级 |
ExdibmbIIBT4Gb |
产品介绍:
随着电子、汽车、航天等高科技行业的高速发展,喷涂工艺对生产环境的净化机温湿度要求越来越高。而喷涂工艺对供风系统的新风量需求大,造成空调设计能耗很大,降低能耗成分喷涂行业空调设备的一个新的发展方向。针对喷涂行业的工艺和能耗特点,结合众多成功案例开发出喷涂线专用净化型组合式空调机组,通过新颖的功能段组合对净化等级及工作间温湿度进行精确的控制,有效降低能耗,受到广泛好评。
本系列产品执行标准如下:
GB3836.1-2010《爆炸性环境 第1部分:设备通用要求》
GB3836.2-2010《爆炸性环境 第2部分:由隔爆外壳“d”保护的设备》
GB3836.4-2010《爆炸性环境 第4部分:由本质安全型“i”保护的设备》
GB3836.9-2006《爆炸性气体环境用电气设备 第9部分:浇封型“m”》
GB3836.15-2000《爆炸性气体环境用电气设备 第15部分:危险场所电气安装(煤矿除外)》
适用范围:
1.本产品适用于石油化工、冶金、纺织、食品、生物工程、制药、仓库、航天航空工程等爆炸性环境中,有温度控制要求的场所;
2.1区、2区危险气体场所
3.IIA、IIB类T1-T4组爆炸性气体或蒸汽环境;
4.环境温度:-5℃~+43℃。